Customization: | Available |
---|---|
Install: | Horizontal |
Medium Temperature: | Cold Water |
Still deciding? Get samples of US$ 50/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Application
Measuring,memorizing and displaying the volume of cold water passing through the pipeline.
Features
1.Adopting volumetric rotary piston of measurement. Magnetic drive and resistance to exterior magnet interference.
2.Register separated from water to keep a clear reading in long-term service. Materials comply
with hygienic standard of potable water.
3. Small start-up flow rate, high precision. Especially suit to the area of good water quality.
Working Conditions
Main Technical Data:
Item No |
Size |
R Flow turndown |
Q4 Max Flow |
Q3 Nominal Flow |
Q2 Transitional Flow |
Q1 Min Flow |
Min Reading |
Max Reading |
mm |
Q3/ Q1 |
m³/h |
L/h |
m³ |
||||
LXH-8E |
8 |
160 |
1.25 |
1 |
10 |
6.25 |
0.00005 |
9999 |
200 |
8 |
5 |
Maximum Permissible Error:
1. in the lower zone from qmin inclusive up to but excluding qt is ±5%;
2. in the upper zone from qt inclusive up to and including qs is ±2% (hot water meter is ±3%).
Note:Technical data conform to ISO4064.
Other products
EXHIBITION
PRODUCTION PROCESS
PACKING & SHIPMENT