Customization: | Available |
---|---|
After-sales Service: | Yes |
Warranty: | 1 Year |
Still deciding? Get samples of US$ 50/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Application
Measuring,memorizing and displaying the volume of cold water passing through the pipeline.
Features
1. Large flow capacity and small pressure lose.
2. Anti-pollution , Built-in stainless steel strainer can save the installation cost.
The measuring mechanism can be removable from the body for checking
maintaining and replacing.
3. Selected high quality materials for steady and reliable characteristic.
4.Vacuum sealed register ensures the dial kept from fog and keep
reading clear in long-term service
MAIN TECHNICAL DATA
water meter temperature grade: T30,T50,T70,T90
Pressure grade: MAP10
Pressure loss grade: △P63
Upstream disturbance grade: U5
Downstream disturbance grade: D0
Main Technical Data:
Item No |
Size |
R Flow turndown |
Q4 Max Flow |
Q3 Nominal Flow |
Q2 Transitional Flow |
Q1 Min Flow |
Min Reading |
Max Reading |
|
mm |
Q3/ Q1 |
Q2/ Q1 |
m³/h |
m³ |
|||||
LXLG-50E |
50 |
100 |
2.5 |
31.25 |
25 |
0.625 |
0.25 |
0.0005 |
999999 |
200 |
6.3 |
0.7875 |
0.125 |
||||||
LXLG-80E |
80 |
100 |
2.5 |
80 |
63 |
1.575 |
0.63 |
||
200 |
6.3 |
2 |
0.315 |
||||||
LXLG-100E |
100 |
100 |
2.5 |
125 |
100 |
2.5 |
1 |
||
200 |
6.3 |
3.15 |
0.5 |
||||||
LXLG-150E |
150 |
100 |
2.5 |
312 |
250 |
6.25 |
2.5 |
0.005 |
999999 |
200 |
6.3 |
7.875 |
1.25 |
||||||
LXLG-200E |
200 |
100 |
2.5 |
500 |
400 |
10 |
4 |
||
200 |
6.3 |
12.6 |
2 |
Maximum Permissible Error:
1. in the lower zone from qmin inclusive up to but excluding qt is ±5%;
2. in the upper zone from qt inclusive up to and including qs is ±2% (hot water meter is ±3%).
Note:Technical data conform to ISO4064.
EXHIBITION
PRODUCTION PROCESS
PACKING & SHIPMENT