• Bulk DN50 to DN300 Ultrasonic Energy Water Flow Meter
  • Bulk DN50 to DN300 Ultrasonic Energy Water Flow Meter
  • Bulk DN50 to DN300 Ultrasonic Energy Water Flow Meter
  • Bulk DN50 to DN300 Ultrasonic Energy Water Flow Meter
  • Bulk DN50 to DN300 Ultrasonic Energy Water Flow Meter
  • Bulk DN50 to DN300 Ultrasonic Energy Water Flow Meter

Bulk DN50 to DN300 Ultrasonic Energy Water Flow Meter

Install: Horizontal
Medium Temperature: Cold Water
Level Measurement: B
Counter Instructions: Digital
Nominal Diameter: DN15-300
Application: Civil, Industrial
Samples:
US$ 50/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company, Other

Basic Info.

Model NO.
YSDAW002
Principle
Ultrasonic Sensor
Medium Pressure
General Water Meter
Work Environment
Normal
Stucture
Integrated
Certificate
ISO9001, CE.UL.Ifa.CQC, Cmaiso4064
Material
Brass, ABS,Iron
Brand
Jy /OEM
Delivery
30working Days After Confirmed for Smart Resident
Transport Package
Strong Cartons with Inner Box, 5/6/12 Pieces/Carto
Specification
Dn15-Dn300
Trademark
JY/OEM
Origin
Zhejiang, China
HS Code
9028201000
Production Capacity
1000 000 Set/Sets Per Month

Product Description

Household Ultrasonic Water Meter
Bulk DN50 to DN300 Ultrasonic Energy Water Flow Meter
Overview
Ultrasonic water meter is intelligent measuring instruments by the temperature sensor, flow sensors and calculators. Calculator used the sensor and through the water of time difference to collect temperature differences and sound waves to complete accurate measurement of water flow. And can provide important application and data for many applications in the pipeline.Mainly used for water metering and monitoring water flow, such as domestic water, central air conditioning systems, equipment, etc.

Technical Parameter
Nominal Diameter
mm
Length L Width B Hight H Flange Connection
        Flange Diameter Bolt Circle Diameter Bolt Size-M
DN50 200 170 215 170 125 4-M16
DN65 200 185 220 185 145 4-M16
DN80 225 200 235 200 160 8-M16
DN100 250 220 255 220 180 8-M16
DN125 250 250 285 250 210 8-M16
DN150 300 285 335 285 240 8-M20
DN200 350 340 405 340 295 12-M20
DN250 450 405 470 405 355 12-M24
DN300 500 460 525 460 410 12-M24

Installation:
Ultrasonic water meter switch screen display mode:
The water meter adopts light sensitive response, you can choose to cover the sensing area with your hand to switch the screen display content.
   Installation positions of all parts of the flow meter should avoid being approached by sun light, flooding, freezing, chemicals and electromagnetic pollutions, and should facilitates dismounting and metering;
Installation of ultrasonic water meter:
1) Before installation should thoroughly clean the system piping,and clear the sand and other debris, avoid water meter failure;
2) Body level or vertical installation, Building water meter installation should be less than 0.8m from the ground;
3) Water flow direction should be consistent with the direction of the arrow marked on the meter body;  
4) Before and after the pipe diameter to be consistent with the body diameter;
5) When installing the water meter, should be reserved length of DN*10 in front of the water meter. Or should be reserved the length of DN*8 behind the water meter. (DN is the diameter of the water meter); . If the conditions are not met, U10 / D5 can also meet the usage standards.


Bulk DN50 to DN300 Ultrasonic Energy Water Flow MeterBulk DN50 to DN300 Ultrasonic Energy Water Flow Meter
Bulk DN50 to DN300 Ultrasonic Energy Water Flow Meter

Production:
Bulk DN50 to DN300 Ultrasonic Energy Water Flow MeterBulk DN50 to DN300 Ultrasonic Energy Water Flow Meter

Product test:
Bulk DN50 to DN300 Ultrasonic Energy Water Flow MeterBulk DN50 to DN300 Ultrasonic Energy Water Flow Meter
Package:
Bulk DN50 to DN300 Ultrasonic Energy Water Flow MeterBulk DN50 to DN300 Ultrasonic Energy Water Flow Meter
Daily maintenance

1. Regularly patrol inspection should be conducted to check the operating status and to see if the voltage of the battery is normal or not after the flow meter is installed.
2. Specialized person should be resorted to have the battery changed when the flow meter operates more than 10 years or less than 10 years but the monitor shows unclear data or the voltage indicates "V", in case affecting the normal performance of the meter.

Transport & Storage
  1.Transport: Meters should avoid being approached by rain,frost, fog after the encasement ,and should be handled as per" This side up" and avoid being damaged by extrusion ,collision ,etc. Transport conditions as per the standard of JB/T9329.
 2.Storage: The warehouse should be acid-free ,base -free ,inflammable-free toxic chemicals-free and other mordant gas and objects. Avoid being exposed to direct sun light and strong electromagnetic interference.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now